The stud size is reversed from the thread specification
M2.5 and M3 self-tapping screws are commonly used in die-cast housings. The outer diameter of the stud is generally twice the nominal diameter of the thread, M3 corresponds to about 6 mm; the column height should not be less than 1.5 times the screwing length, the screwing length of M3 is calculated as 5 mm, and the column height is left to 7 mm. When the size is insufficient, the screw will push against the bottom of the column when it is turned to the end, causing additional stress and causing the column to crack from the root.
The bottom of the column cannot be made at right angles. The bottom fillet should be more than 0.5 mm, the column body should have a draft angle of one to two degrees, and a circle of triangular ribs should be added at the intersection between the column root and the shell. The height of the ribs should be approximately one-third of the column height. These details determine whether the stress can be smoothly transmitted to the shell during tightening.
The choice between self-tapping and embedded nuts
Self-tapping screws are low in cost and fast to assemble, and are suitable for parts such as cover plates that are rarely disassembled and assembled. When aluminum die-casting parts are repeatedly disassembled and assembled, the threads will be cut successively, and the preload force will decrease significantly after the third time. For shells that require frequent maintenance, use pre-embedded copper nuts or press-fit wire thread inserts. The thread strength is borne by the metal parts, and the shell is only responsible for fixing.
Pay attention to the wall thickness of embedded nuts. Press-fitting copper nuts requires that the physical thickness around the cylinder should not be less than 2 mm. Air is easily trapped in this area during die-casting, and a separate vent must be opened on the mold. Do a thrust test after press-fitting, and the nut must not be rotated or pulled out.
How to check whether a stud is qualified?
There are three commonly used inspections: torque test, pull-out force test and profile inspection. For the torque test, tighten at 1.2 times the design torque, and then loosen after holding for ten seconds to see if there are any cracks in the cylinder; for the pull-out force test, use a tensile gauge to load along the axial direction, and record the value when the thread slips; for cross-section inspection, take the first piece of the same batch and cut it open to see if the air hole inside the cylinder exceeds one-tenth of the cross section.
Stud density also affects strength. When the distance between columns around the cover plate is too large, the cover plate will warp after the force is applied to the middle section, and the sealing ring will be partially compressed. The distance is generally controlled within 60 mm. There must be columns at the corners, and one can be added in the middle of the long side.
- There should be no visible cracks and cold insulation at the column root;
- Screws should be screwed in smoothly and no jamming is allowed;
- The height deviation of columns in the same batch should be controlled within 0.15 mm;
- Retest the torque after disassembly and assembly five times, and the attenuation should not exceed 20%.
Weijiaxin checked the relationship between studs and ribs during the shell mold review stage, adjusted the gate position where the wall thickness was uneven, and reduced the air holes in the cylinder. If the structure is done correctly, slippage and cracking on the assembly line will naturally be reduced.