Why do old samples fail?
The surface of the color plate will slowly change when it is placed in the workshop and exposed to light and dust every day. The powder-coated sample will turn yellowish due to the influence of ultraviolet rays and moisture, and the surface gloss of the liquid paint sample will decrease as it is wiped more often. Taking a changed sample to match the color is equivalent to using the wrong ruler to measure the length. The direct reason for this round of updates is that some commonly used outdoor colors have been used for too long, causing more disputes during visual comparison. The failure of a sample does not only depend on the color, but the gloss and surface texture will also change. When comparing, these three items should be looked at together.
How to manage the new samples
The updated samples are produced in sets according to the color number. They are sprayed at the same time, the same batch of powder or paint, one for the flat surface and one for the curved surface. The color number, process, film thickness and production date are marked. The sample should be made in duplicate, one should be kept on the comparison table, and the other should be sealed for future reference; the sealed piece should not be exposed to light or come into contact with hand sweat.
The comparison conditions are also fixed. Compare the standard light source box, and write the light source and observation angle into the work instructions to avoid one looking by the window and the other under the lamp. A colorimeter is used as an auxiliary, and the measuring point is selected in a flat area. The curved surface and ribs are only used for visual reference, because curvature will affect the reading. The sample on the comparison table is placed flat and fixed, and is not picked up casually and compared against the workpiece. The judgment changes when the angle changes.
What it means to customers
Most color disputes are not caused by bad spraying, but by different reference materials between the two parties. The new sample is sent together with the first batch of goods. The customer has a set of standard parts that have the same origin as the production line. There is a common benchmark when discussing colors when returning orders. When changing the powder batch, first spray a small sample and compare it with the sealed sample, and then go online to avoid rework of the entire batch.
Weijiaxin writes the validity period and re-inspection nodes of the model into the painting operation file, and it is forced to be redone when it expires. It no longer relies on memory to determine which panel can still be used. The sample number corresponds to the color number one-to-one, and a list is attached when the product is shipped. If the customer is not sure of the number, he or she can take a photo and send it back for confirmation.
- The color number, process, film thickness and production date are marked on the sample, and any missing items will not be put into use;
- Compare under a standard light source, the color difference is controlled within 1.5, and there are no obvious seams visually;
- The sample is sealed and stored in a dark place, and will be remade and kept for files when it expires;
- For batches of replacement powder or paint, a small sample will be compared first, and the entire batch will be put online after passing the test.
Color is the most intuitive quality indicator of the shell, and it is also the indicator that is most likely to be aliased between batches. Only by fixing the template, light source and judgment method can color consistency have an executable basis.